Paper Transfer Quality Standards
M0C3/M0C4/M0C5/M0C6/M0C7 3-4 SM
3.3 PAPER TRANSFER QUALITY STANDARDS
Item Specification Remarks
Registration Single Side:
Width: 0±2.5mm (Main Scan Direction)
Vertical: 0±2.0mm (Sub Scan Direction)
Duplex:
Width: 0±2.5mm (Main Scan Direction)
Vertical: 0±2.0mm (Sub Scan Direction)
Scale
Skew Single Side:
±1.0mm/100mm or less (Less than B5 SEF)
±1.2mm/200mm or less (B5 SEF or more)
Duplex:
±1.0mm/100mm or less
Except by-pass tray.
These standards are determined using the standard paper with the standard conditions. The
values may change depending on environmental conditions such as temperature, humidity, and
paper type.