EasyManua.ls Logo

Ricoh SP 3710DN - Fusing Temperature Control

Ricoh SP 3710DN
333 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Fusing and Exit
SM 7-39 M0C3/M0C4/M0C5/M0C6/M0C7
Detailed
Descriptions
Fusing Temperature Control
Callout Item
A Warm up mode
B Standby mode
C Print mode
D Standby mode
E Energy saver mode 1
F Energy saver mode 2
When the main switch is turned on, the CPU turns on the fusing lamp using the soft start
process. (The soft start process prevents the room lights from flickering.) The lamp stays on
until the thermistor detects the standby temperature. Then the CPU maintains this temperature
using on-off control. To start printing, the CPU raises the temperature to the printing
temperature.
The fusing temperature for each condition is as follows: