Make sure that the VitaLite-E and C disinfection process has been running for at
least ten minutes before taking a sample.
Sampling method
Start with the upper sampling tap (disinfected water).
Sterilize the sampling tap with alcohol or burn the tap clean with a burner.
Open the sampling tap and let the water run into the bucket for approximately
two minutes.
Put the latex gloves on and fill the sample bottle directly from the tap.
Close the tap, then close the sample bottle.
Wrap and cool the sample bottle.
Repeat this procedure for the lower sampling tap (drain water).
Last step
After taking samples, send the cooled samples as soon as possible to the
laboratory.
VitaLite
49