<M> Settings / Drain tank
Height of maximum level [m]
Here you enter the height of the water level (in metres) at
which the maximum volume of water is measured in the
drain tank.
h
max
Maximum range of level sensor [m]
Here you enter the height of the water level (in metres) at
which the maximum sensor level is measured in the drain
tank.
Level m
3
= Minimum volume +
(((Level percentage/100) * Maximum range of level
sensor) Height of minimum level) *
((Maximum volume Minimum volume)/
(Height of maximum level - Height of minimum level))
h
100%
Level fixed at 50%
If no level sensor is present, then the measured level can
be set at a fixed level of 50%. This setting is useful, for
example, if a rainwater reservoir is used.
Only set to Yes
if no level
sensor is
present.
8.10.2 Disinfected tanks
<M> Settings / Disinfected tank
Minimum volume [m3]
Here you enter the minimum volume of water (in cubic
metres) that the disinfected tank must contain.
V
min
Maximum volume [m3]
Here you enter the maximum volume of water (in cubic
metres) that the disinfected tank may contain.
V
max
Height of minimum level [m]
Here you enter the height of the water level (in metres) at
which the minimum volume of water is measured in the
disinfected tank.
h
min
Height of maximum level [m]
Here you enter the height of the water level (in metres) at
which the maximum volume of water is measured in the
drain tank.
h
max
VitaLite
90