<M> Settings / Drain groups / Control characteristics
Dose flow gain
This sets the degree to which the disinfected (water) valve should
open or close in order to achieve the calculated flow, should it
differ from the measured flow.
Control pulse = Calculated flow - Measured flow x Dose flow gain
Max. flow control pulse [s]
This sets the maximum calculated control pulse for adjusting the
position of the servo valve per 10-second cycle.
Minimum blending ratio [%]
This sets the minimum blending ratio that can be calculated based
on the volume of water in the drain tank.
Maximum blending ratio [%]
This sets the maximum blending ratio that can be calculated based
on the volume of water in the drain tank.
Drain tank vol. min. blending ratio [m
3
/h]
If the volume of water in the drain tank drops below the value set
here, then the minimum blending ratio will be used.
Drain tank vol. max. blending ratio [m
3
/h]
If the volume of water in the drain tank rises above the value set
here, then the maximum blending ratio will be used.
8.8 Cleaning quartz tubes settings
<M> Settings / Clean quartz tubes
Control
Safeguards
Control characteristics