<M> Settings / Drain groups / Control
Enable discharge
l No: The water flowing past the quartz tubes during the post-
flush phase will be fed back to the drain tank.
l Yes: The water flowing past the quartz tubes during the post-
flush phase will be discharged from the system as wastewater.
8.7.5 Drain groups / Safeguards
<M> Settings / Drain groups / Safeguards
Minimum lamp on-time [hh:mm:ss]
This sets the minimum amount of time that the UV lamps
must remain switched on continuously, before they may be
switched off. If the UV lamps are switched off before this
time has elapsed, then the alarm message 'UV lamps on-
time too short' will be generated.
00:30:00 h
Minimum flow [l/min]
If the flow rate drops below the value set here, then the
alarm message 'Flow too low' will be generated. This alarm
will be generated once the time set for 'Delay flow alarm'
has elapsed.
This setting does NOT apply during disinfection.
Minimum flow [l/min]
If the flow rate rises above the value set here, then the
alarm message 'Flow too high' will be generated. This alarm
will be generated once the time set for 'Delay flow alarm'
has elapsed.
This setting does NOT apply during disinfection.
Minimum dose flow [l/min]
This sets the minimum flow rate that may be calculated
during dose control. This value may not be lower than the
'Minimum design flow'.
This setting only applies during disinfection based on the
radiation dose.
Maximum dose flow [l/min]
This sets the maximum flow rate that may be calculated
during dose control. This value may not be higher than the
'Maximum design flow'.
This setting only applies during disinfection based on the
radiation dose.