EasyManua.ls Logo

Ridder VitaLite-E - Unit Characteristics

Ridder VitaLite-E
110 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
<M> Settings / Unit / Safeguards
Delay blending ratio alarm [hh:mm:ss]
This sets the duration that the 'Measured blending ratio' must
continuously remain below the 'Calculated blending ratio' minus the
'Blending ratio deviation', or above the 'Calculated blending ratio' plus
the 'Blending ratio deviation', for an alarm message to be generated.
Delay EC alarm [hh:mm:ss]
This sets the duration that the 'Measured EC' must continuously remain
below the 'Calculated EC' minus the 'Minimum EC zone', or above the
'Calculated EC' plus the 'Maximum EC zone', for an alarm message to
be generated.
Disinfection pH alarm delay [hh:mm:ss]
This sets the duration that the 'Measured pH' must continuously
remain below the 'Calculated pH' minus the 'Minimum pH zone', or
above the 'Calculated pH' plus the 'Maximum pH zone', for an alarm
message to be generated.
Delay cleaning pH alarm [hh:mm:ss]
This sets the duration that the 'Measured pH' must continuously
remain below the 'Calculated pH' minus the 'Minimum pH zone', or
above the 'Calculated pH' plus the 'Maximum pH zone', for an alarm
message to be generated.
Ext. contact definition
Here you select which action should be taken if the external contact
signal is received.
l None: No action.
l Pause: The unit will be paused.
l Stop: The unit will stop.
l Pause and resume: The unit will first be paused and then
resume when the external contact signal is no longer received.
l Pause and alarm: The unit will be paused and generate an
alarm.
8.6.3 Unit characteristics
Most of these values have been pre-entered. Check the values and adjust them as
needed. The K-factor of the litre counter depends on the tube's inner diameter. You
can check the water flow through the sight glass.
You can read the correct DN size on the first PVC coupling piece after the litre
counter.