8.7.2 Start conditions
<M> Settings / Drain groups / Start conditions
Manual control (from Synopta)
l Start: Start disinfection for the selected drain group. If
the unit is busy, then the start command will be
queued.
l Pause: Pause disinfection for the drain group that is
currently active.
l Stop: Stop disinfection for a drain group if it is
currently active. If a start command for this drain
group is currently queued, then it will be removed from
the queue.
Enable automatic disinfection
l No: Disinfection will not start automatically.
l Yes: Disinfection will start automatically when the
start conditions are met.
Yes
Start time disinfection [hh:mm:ss]
This sets the time from which disinfection may start
automatically.
You can set either an absolute time, or a time in relation to
sunrise/sunset.
For example,
10:00:00 h.
End time disinfection [hh:mm:ss]
This sets the time until which disinfection may start
automatically.
You can set either an absolute time, or a time in relation to
sunrise/sunset.
For example,
23:00:00 h.
Di tank vol. start disinf per. 1 - 4 [m
3
]
In full: Drain tank volume for start disinfection in period 1 -
4. If the volume of water in the drain tank rises above the
value set here, then disinfection will start during the period in
question.
The drain
tank must
contain a
sufficient
amount of
water to
allow for at
least 5 hours
of
disinfection
For example:
40 m
3
at 8
m
3
/hour.
VitaLite