<M> Settings / Drain groups / Start conditions
Di tank vol. start disinf per. 1 - 4 [m3]
In full: Drain tank volume for start disinfection in period 1 -
4. If the volume of water in the disinfected tank drops below
the value set here, then disinfection will start during the
period in question.
The
disinfected
tank must be
sufficiently
empty to
allow for at
least five
hours of
disinfection
For example:
40 m
3
at 8
m
3
/hour.
Di tank vol. stop disinf per. 1 - 4 [m3]
If the volume of water in the disinfected tank rises above the
value set here, then disinfection will stop during the period in
question.
The
disinfected
tank must
have
sufficient
capacity to
allow for at
least five
hours of
disinfection
For example:
40 m
3
at 8
m
3
/hour.
Min. m3 to be disinf. period 1 - 4 [m3]
The minimum number of cubic metres of drain water to be
disinfected for the period in question. Only once this amount
of water has been disinfected can the disinfection process be
interrupted by another drain group with a higher priority. If 0
is set here, then the drain group cannot be interrupted. If a
drain group is interrupted by another drain group, then the
warm-up phase the UV lamps will be skipped for this other
drain group.
Please
ensure that
the minimum
lamp on-time
of five hours
is
maintained.
Drain group priority
Here you select the priority of a drain group. A drain group
with a higher priority than another drain group takes
precedence over that group.
Normally 1
Only
applicable if
more than
one drain
tank is
present.
VitaLite