<M> Settings / Filter flushing / Control
Start time filter flushing [hh:mm:ss]
This allows you to set the time from which the filter
may be flushed automatically.
00:00:00
End time filter flushing [hh:mm:ss]
This allows you to set the time until which the filter
may be flushed automatically.
23:59:00
Flush time per filter [hh:mm:ss]
This sets the duration that the filter will be back-
flushed. Back-flushing will stop sooner if the 'Flush
volume per filter' is reached.
00:05:00
Check the discharge
water. If the water is
still dirty, set a higher
value.
Adjust the discharge
valve based on the
information provided
on the filter.
Flush volume per filter [l]
This sets the volume of water in litres that the filter
will be back-flushed with. Back-flushing will stop
sooner if the 'Flush duration per filter' is reached.
10000, filter flushing
will then last approx. 5
minutes.
Delay time after last filter [hh:mm:ss]
After the filter has been flushed, the unit will
become available again for other processes once
the delay time set here has elapsed.
00:03:00
Quantity for start flushing [m3]
This sets the amount of water that must pass
through the filter, since the last time that the filter
was flushed, in order for the filter flushing to start.
Rule of thumb: Value
= 10 x rated capacity
Interrupt disinfection process
l Yes: Disinfection may be interrupted to flush
the filter if the 'Quantity for start flushing' has
passed through the filter. Disinfection will
continue once the filter has been flushed.
l No: Disinfection may not be interrupted to
flush the filter; filter flushing will not start
until disinfection has been completed and the
start conditions are met.
Yes (always)
Flush with fresh water
l No: Flush filter with water from a drain tank.
l Yes: Flush filter with water from a fresh
water tank.
No, unless this is
specifically possible
and the customer
explicitly requests it.
VitaLite