8. PARAMETER DESCRIPTION
IMR02C15-E4
8-15
Timer 1
Timer 2
Timer 3
Timer 4
Factory default setting:
The screen is not displayed.
Set Timer time in the Timer function to change Set value (SV).
Data range Factory set value
00 minute 01 seconds to 99 minutes 59 seconds or
00
hour 01 minutes to 99 hours 59 minutes
[Factory set value of time unit of timer: 0
(min.: sec.)]
00:01
Timer time is not displayed as the default when the block selection at F02
[S.F02] (P. 8-65) is set to “1: No display” in the Engineering mode.
To show the parameter, set the value to “0: Display.”
Set Timer time unit (TMU) at Function block 70 [F70
.
] (P. 8-136) in the
Engineering mode.
For the operating procedure of the Timer function, refer to 7.2 Timer
Function (P. 7-5).
Related parameters
Parameter setting mode:
• Timer function (P. 8-16)
• Repeat execution times (P. 8-17)
Engineering mode:
• Timer 1, Timer 2, Timer 3, Timer 4 (P. 8-63)
• Timer time unit (P. 8-136)