V L F > H F R E C E I V E R S
f
R & S E K 8 9 5 / R & S E K 8 9 5
User Manual
f
Storing and Clearing
3.1.15 Storing and Clearing
By actuation of softkeys more and MEM (R&S
EK!895) or of softkey MEM (R&S EK 896) the
storage menu is called up. The menu offers the
following functions:
f CLA (clear all channels)
f CLCH (clear a particular channel)
f STCH (store into a particular channel)
f STO (store into the next free channel with
the lowest channel number).
Up to 1000 complete receiver settings can be
stored failure>safe into the channels (0 to 999).
A complete receiver setting consists of fre>
quency, bandwidth, BFO frequency, demodula>
tion mode, control type and time, frequency
deviation and offset, baud rate, polarity, TTY
status, error flag and DGC value.
It is possible to store the current receiver
setting into the next free channel with the
lowest channel number (Æ STO) or into a
channel (Æ STCH) to be entered via the
numeric keypad.
In the channels, individual receiver settings can
be altered or complete receiver settings can be
cleared (inhibited) via the channel editing
menu (see 3.1.16).
It is possible to clear (inhibit) all channels (Æ
CLA) or clear (inhibit) one particular channel
(Æ CLCH) entered via the numeric keypad.
Channels which have been cleared via the key
CLR or via the softkey CLCH or CLA are still
physically available, that is, the channel is
inhibited. Via the function RAM, however, the
memory content is overwritten with logic
naughts (see 3.1.19.5).
In the operating modes CHANNEL and FIXED
CHANNEL and via the function CHS inhibited
channels cannot be called up.
It is, however, possible to reactivate inhibited
channels via the channel editing menu (see
3.1.16).
3.1.15.1 Clearing All Channels
Upon actuation of softkeys more and MEM
(R&S EK 895) or of softkey MEM (R&S EK 896) as
well as of softkey CLA the following display
appears:
CLEAR ALL YES NO
Actuate softkey YES to confirm that all chan>
nels be cleared.
Actuate softkey NO to indicate that not all or
no channels are to be cleared.
3.1.15.2 Clearing a Particular Channel
Upon actuation of softkeys more and MEM
(R&S EK 895) or of softkey MEM (R&S EK 896) as
well as of softkey CLCH the following display
appears:
CLEAR CH _ ENT
The flashing cursor (_) indicates that an entry is
being expected. Enter the channel number via
the numeric keypad.
Range of entry: ............. 0 to 999
3.1.15.3 Storing into a Particular Channel
Upon actuation of softkeys more and MEM
(R&S EK 895) or of softkey MEM (R&S EK 896) as
well as of softkey STCH the following display
appears:
STORE CH _ ENT
The flashing cursor (_) indicates that an entry is
being expected. Enter the channel number via
the numeric keypad.
Range of entry: ............. 0 to 999
3.1.15.4 Storing into the Next Free
Channel
Actuate softkeys more and MEM (EK 895) or
softkey MEM (EK 896) as well as softkey STO.
6164.0717.02_01
> 3.36 >