Basic Settings
A3.3.6 Control Type
Command syntax:
Code: R
Parameter: ................... a
Possible entries / replies
0 = AGC 4 = AGC + DGC
1 = AGC + DGC 5 = MGC
2 = AGC + DGC 6 = AGC + MGC
3 = AGC 7 = AGC + MGC
Note:
For reasons of compatibility with the VLF>HF
Receiver R&S EK 085, the type of control se>
lected by the commands R1 and R2 is the same
for both.
Example 1:
Activating type of control AGC
Command = rAxxR0?
Example 2:
Inquiry of the currently effective type of con>
trol
Command = rAxxR??
Æ Reply = rAxxR0?
The type of control AGC is currently effective.
A3.3.7 Control Time
Command syntax
Code: DT
Parameter: ................... a
Possible entries / replies:
0 = 25 ms
1 = 150 ms
2 = 500 ms
3 = 1 s
4 = 3 s
Example 1:
Activating the control time 500 ms
Command = rAxxDT2?
Example 2:
Inquiry of the currently effective control time
Command = rAxxDT??
Æ Reply = AxxDT2?
The control time of 500 ms is currently effec>
tive.