V L F > H F R E C E I V E R S
f
R & S E K 8 9 5 / R & S E K 8 9 6
User Manual
f
Fault Recognition During Operation (BIT)
4.2.2.4 Fault Recognition During Operation by Initiation of the BIT
R&S EK 895 R&S EK 896
Actuate softkeys MORE, MORE, SYS and BIT. Actuate softkeys SYS and BIT.
Main menu *
MOD CHM MEM SCN SYS >
System functions menu *
VERS OPT CM BIT >
NOTCH
PBT
CHFRQ
BFO
LED Test
LED Test
FRQ
CH
NOTCH
PBT
BFO
Main menu 2
CHM MEM SQL more
Main menu
MOD GAIN BW SCN more
System functions menu
VERS OPT CM BIT more
Main menu 3
M/S SYS SPEC
MORE
MORE
Via the LED test the function of LEDs FRQ, BFO, CH and PBT / NOTCH is checked.
Æ All LEDs are illuminated.
As soon as one of the LEDs fails to be illuminated,
f replace control unit 2 ∫LOCAL∫ (R&S EK 895, = option 'Control Unit R&S GB 890') acc. to 4.3.3
or
f replace control unit (R&S EK 896) acc. to 4.3.4.
6164.0717.02_01
> 4.10 >