A3.8 System Functions
The following system functions are possible:
f Addressed operation
f Inquiry of software version
f Inquiry of IF filter bandwidths
f Inquiry of options
f Signal BYPASS
f Inquiry of operating status
f Inquiry of scanning status
f Inquiry of error status
f Initiating a reset
f Activating command IF
f Disabling or enabling local control
f Inquiry of software type and ident. no.
f Inquiry of software version and DSP version
A3.8.1 Addressed Operation
Command syntax:
Code: A
Parameter: ................... a
Range: ......................... 0 to 99
Note:
For unaddressed operation, entry of the ad>
dress is not required. Command blocks be>
ginning with address A00 are accepted by all
receivers, irrespective of the set receiver ad>
dress.
Example 1:
Transferring a command block to the receiver
with the address A12
Command = rA12<command block>?
Example 2:
Transferring a command block to all receivers
Command = rA00<Command block>?