A3.7.7 Initiation of BIT and / or
Inquiry of BIT Status
Command syntax:
Code: BI
Possible replies
Parameter: .................... a
0 = no error
10 = synthesizer missing
1 = synthesizer defective
20 = HF unit missing
2 = HF unit defective
5 = module bus defective
60 = IF / AF processor missing
6 = IF / AF processor defective
7 = IF Converter R&S UX 895 defective
Command: BIs (initiate BIT)
Note:
As soon as a reply other than BI0 is indicated,
carry out troubleshooting acc. to chapter 4.2.
Example 1:
Inquiry of the BIT status
Command = rAxxBI??
Æ Reply = rAxxBI0?
The receiver works perfectly.
Example 2:
Initiation of BIT and inquiry of BIT status
Command = rAxxBIs,??
Æ Reply = rAxxBI0?
The receiver works perfectly.
Example 3:
Initiation of BIT and inquiry of BIT status
Command = rAxxBIs,??
Æ Reply = rAxxBI10,20?
The modules synthesizer and HF unit are mis>
sing.
A3.7.8 Inquiry of CM Status
Command syntax:
Code: C
Possible replies
Parameter: .................... a
0 = no error
1 = synthesizer defective
4 = IF / AF processor defective
5 = synthesizer and IF / AF processor
defective
Note:
If during operation a change in the CM status
occurs, this change is automatically signalled to
the PC. However, this does not apply to bus
operation. As soon as a reply other than C0 ap>
pears, carry out troubleshooting acc. to chap>
ter 4.2.
Example:
Inquiry of CM status
Command = rAxxC??
Æ Reply = rAxxC0?
The synthesizer and the IF / AF processor both
work perfectly.
A3.7.9 Inquiry of Receive Level
(see A3.7.26 for extended range)
Command syntax:
Code: L
Possible replies
Parameter: ................... a
Range: .......................... 0 to 120
Resolution: .................... 1 dBoV
EMF
Example:
Inquiry of the currently effective receive level
Command = rAxxL??
Æ Reply = rAxxL65?
The currently effective receive level is
65!dBoV
EMF
.