V L F > H F R E C E I V E R S
f
R & S E K 8 9 5 / R & S E K 8 9 6
User Manual
f
Special Functions
A3.7.13 Inquiry of Channel Contents
Command syntax:
Code: K
Parameter: .................... a
Possible entries
Range: .......................... 0 to 999
Example 1:
Inquiry of the contents of channel 125
Command = rAxxK125,??
Æ Reply =
rAxxK125F6000000I5B800W1R2DT2D45?
In channel 125 the following settings are
stored:
f Frequency: F6000000 = 6 MHz
f Modulation mode: I5 = CW
f BFO frequency: B800 = 800 Hz
f Bandwidth: W1 = 150 Hz
f Control type: R2 = AGC+DGC
f Control time: DT2 = 500 ms
f DGC value: D45 = 45 dBoV
EMF
Example 2:
Inquiry of current receiver setting
Command = rAxxK??
Æ Reply =
rAxxK
≤≥
F12345678I3B>100W31R0DT1D25?
Note:
The blank '
≤≥
'
following the letter K means,
that there is no channel set.
The following settings are effective at the mo>
ment:
f Operating mode: K
≤≥ =
MANUAL
f Frequency: F12345678 = 12345.678 kHz
f Modulation mode: I3 = LSB
f BFO frequency: B>100 = >100 Hz
f Bandwidth: W31 = 3.1 kHz
f Control type: R0 = AGC
f Control time: DT1 = 150 ms
f DGC value: D25 = 25 dBoV
EMF
Example 3:
Inquiry of current receiver setting
Command = rAxxK??
Æ Reply =
rAxxK232F800000I1B
≤≥
W60R0DT1D25?
The following settings are effective at the mo>
ment:
f Operating mode: K232
=
CHANNEL
f Frequency: F800000 = 800 kHz
f Modulation mode: I1 = AM
f BFO frequency: B
≤≥
= none
f Bandwidth: W60 = 6.0 kHz
f Control type: R0 = AGC
f Control time DT1 = 150 ms
f DGC value: D25 = 25 dBoV
EMF
Example 4 (with option EK 895S7):
Inquiry of contents of channel 125
Command = rAxxK125,??
Æ Reply =
rAxxK125F6000000I5B800Q1225,1
R2DT2D45?
In channel 125 the following settings are
stored:
f Frequency: F6000000 = 6 MHz
f Modulation mode: I5 = CW
f BFO frequency: B800 = 800 Hz
f Quasi>continuous bandwidth:
Q1225 = 1225 Hz
f Control type: R2 = AGC+DGC
f Control time: DT2 = 500 ms
f DGC value: D45 = 45 dBoV
EMF
6164.0717.02_01
> A3.30 >