V L F > H F R E C E I V E R S
f
R & S E K 8 9 5 / R & S E K 8 9 6
User Manual
f
Separate Functions 2
3.1.21.1 Switching Remote Control Off
After switch>on the receiver status is Remote /
Local. That means the receiver can be con>
trolled both via the front panel and the remote
control interface.
Actuate key MENU1 and softkey LOC.
Now the receiver status is Local. That means
control via the remote control interface is now
impossible except for command REM (see
A4.9.11)
3.1.21.2 Storage into the Buffer
Actuate key MENU1 and softkey ME+.
Now the entire receiver setting is stored in the
buffer.
3.1.21.3 Calling up the Buffer Contents
Actuate key MENU1 and softkey ME>.
The receiver settings stored in the buffer are
now activated.
3.1.21.4 Starting or Stopping Scanning
By actuation of key MENU 1 and softkey S / C
an activated scan process is stopped or a
stopped scan process is resumed.
If after actuation of softkey S / C the display
FREQUENCY in the frequency field is flashing,
frequency scanning was reactivated.
If after actuation of softkey S / C the display
CHANNEL in the channel field is flashing,
channel scanning was reactivated.
3.1.21.5 Activating the Digitally Tuned RF
Selector R&S FK 896D (Option)
By actuation of key MENU 1 and softkey BYP
the Digitally Tuned RF Selector R&S FK 896D is
activated. The HF signal is routed via the R&S
FK 896D to the HF unit.
3.1.21.6 Deactivating the Digitally Tuned
RF Selector R&S FK 896D (Option)
By actuation of key MENU 1 and softkey BYP
the R&S FK 896D is deactivated. The HF signal is
routed directly to the HF unit. In the display
now BYP is underlined.
3.1.21.7 Selecting the USB Rx Filter Mode
(R&S EK 896)
Upon actuation of key MENU 1 and softkey
SSBM calls up the following USB Rx filter mode
menu:
f VOICE
f DATA
The currently effective SSB Rx filter mode is in>
dicated on the display by an asterix of the rele>
vant value, e.g. VOICE*.
The setting of the own local>controlled re>
ceiver is displayed by an underline, e.g. DATA
.
Note:
When changing the modulation mode via the
remote interface the SSB Rx filter mode is reset
to DATA. The change of the modulation mode
via the MMI has no effect on the SSB Rx filter
mode.
3.1.21.8 Selecting the Bargraph Mode
(R&S EK 896)
Upon actuation of key MENU 1 and softkey
BAR calls up the following bargraph mode
menu:
f dBuV (level, resolution of 1 dBuV)
f dS (levelS value, resolution of 0.5 S)
f NORM (level, resolution of 5 dBuV)
The currently effective bargraph mode is idi>
cated on the display by an underline of the
relevant value, e.g. dS
.
If setting dBoV or dS is selected, the receiver
level will be displayed instead of modulation
mode and control type and time.
After pressing softkey more and after making
an entry, the modulation mode and control
type will be displayed for 3 s.
6164.0717.02_01
> 3.62 >