V L F > H F R E C E I V E R S
f
R & S E K 8 9 5 / R & S E K 8 9 6
User Manual
f
Lists of Faults
4.2.1.2 BIT Messages
No. Fault message Measure
1GO
2 SYNTH NOGO Replace synthesizer acc. to 4.3.6.
3 SYNTH MISSING Install synthesizer acc. to 4.3.6.
4 RF UNIT NOGO Replace HF unit acc. to 4.3.7.
5 RF UNIT MISSING Install HF unit acc. to 4.3.7.
6 IF / AF NOGO Replace IF / AF processor acc. to 4.3.9.
7 IF / AF MISSING Install IF / AF processor acc. to 4.3.9.
8 PROC UNIT NOGO Replace modules one after another until the fault has
been eliminated. If by this measure the fault cannot be
found, send the entire receiver for repair.
9 FAILED Actuate key MENU and switch receiver to local opera>
tion acc. to 3.1.18.7. Then switch receiver off and on
again.
10 IF CONV NOGO Replace optional IF Converter R&S UX 895 acc. to
4.3.13.
6164.0717.02_01