V L F > H F R E C E I V E R S
f
R & S E K 8 9 5 / R & S E K 8 9 6
User Manual
f
Squelch Type
3.1.24 Squelch Type Setting
Note:
Make sure that the squelch function (see
3.1.20.4) is switched on.
The type of squelch function can be selected by
actuating softkeys in the squelch setting menu.
The following types of squech function are
available:
f LEV (level squelch)
f SYL (syllabic squelch)
f L+SYL (combined level and syllabic
squelch)
Level squelch works as a function of pre>
selected level of the wanted signal strength.
Only when this threshold is exceeded will the
audio signal be unmuted.
Syllabic squelch acts upon the voice part of
wanted signal. I.e. the wanted signal is checked
for voice signal parts, and only if such voice
signal parts are contained, will the audio signal
be unmuted.
3.1.24.1 Selecting Level Squelch and/or
Altering Level Squelch Threshold
Upon actuation of softkey more (R&S EK!895)
or of key MORE (R&S EK 896) as well as of soft>
keys SQL and LEV the following display ap>
pears:
LEV. THLD xxx _ dB
o
V ENT
(xxx= last stored level squelch threshold)
The flashing cursor (_) indicates that an entry is
being expected. Enter new level squelch thre>
shold via the numeric keypad.
Range of entry: .............. 0 to 120 dBoV
Resolution: .................... 1 dBoV
Via the ENT function the entry is stored.
The display LEV is now underlined.
In order to increase the new level squelch thre>
shold in steps of 1 dBoV turn tuning knob
clockwise.
In order to decrease the new level squelch
threshold in steps of 1 dBoV turn tuning knob
counter>clockwise.
3.1.24.2 Selecting Syllabic Squelch and/or
Altering Syllabic Squelch
Threshold
Upon actuation of softkey more (R&S EK!895)
or of key MORE (R&S EK 896) as well as of soft>
keys SQL and SYL the following display ap>
pears:
SYL. THLD xxx _ % ENT
(xxx= last stored syllabic squelch threshold)
The flashing cursor (_) indicates that an entry is
being expected. Enter new syllabic squelch
threshold via the numeric keypad.
Range of entry: .............. 0 to 100 %
Resolution: .................... 1
Via the ENT function the entry is stored.
The display SYL is now underlined.
In order to increase the new syllabic squelch
threshold in steps of 1 % turn tuning knob
clockwise.
In order to decrease the new syllabic squelch
threshold in steps of 1 % turn tuning knob
counter>clockwise.
3.1.24.3 Selecting Level/Syllabic Squelch
Note:
The thresholds acc. to 3.1.24.1 and .2 are used .
Actuate softkey more (R&S EK!895) or key
MORE (R&S EK 896) as well as softkeys SQL and
L+SYL .
The display L+SYL is now underlined.
6164.0717.02_01
> 3.68 >