Editing the Channel Contents
3.1.16 Editing the Channel
Contents
Note:
Channel manipulations (CHM) are only possible
if receiver settings were already stored acc. to
3.1.15.
In the channel manipulations menu, it is not
the currently effective receiver setting which is
indicated but that of the called>up channel.
Channel manipulations do not alter the current
receiver setting, that is, receive operation is not
affected.
Upon actuation of softkeys more and CHM
(R&S EK!895) or of softkey CHM (R&S EK 896)
the channel number in the channel field
flashes (indicating that the channel editor is
activated) and the LED assigned to key CH is
illuminated. Call up the channel whose
contents are to be edited acc. to 3.1.14.
By way of direct key actuation or softkey
actuation in the channel manipulations menu,
the operator can carry out the following
actions:
f Alter the frequency
(see 3.1.7)
f Alter the demodulation mode
(see 3.1.8)
f Alter the bandwidth
(see 3.1.9)
f Alter the control type
(see 3.1.11)
f Alter the control time
(see 3.1.12)
f Alter the BFO frequency
(see 3.1.13)
f Alter the digital threshold
(see 3.1.16.1)
f Inhibit a channel
(see 3.1.16.2)
f Reactivate a channel
(see 3.1.16.3
3.1.16.1 Entering the Digital Threshold
Note:
The bargraph indicates the digital threshold
stored in the channel.
Upon actuation of softkeys more and CHM
(R&S EK!895) or of softkey CHM (R&S EK 896) as
well as of softkey THLD the following display
appears:
THRESHOLD xx_ dB
o
V
(xx=digital threshold last stored)
The flashing cursor (_) indicates that an entry is
being expected. Enter the new digital thresh>
old via the numeric keypad.
Range of entry: .......... 0 to 120 dBoV
Resolution: ................... 1 dBoV
3.1.16.2 Inhibiting a Channel
Upon actuation of softkeys more and CHM
(R&S EK!895) or of softkey CHM (R&S EK 896) as
well as of key CLR the following display
appears:
UNUSED
3.1.16.3 Reactivating a Channel
Upon actuation of softkeys more and CHM
(R&S EK!895) or of softkey CHM (R&S EK 896) as
well as of key ENT the displays for modulation
mode and control type and time will appear.
6164.0717.02_01