EasyManua.ls Logo

Rohde & Schwarz 890 Series - A3.9 List of Commands

Rohde & Schwarz 890 Series
406 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
V L F > H F R E C E I V E R S
f
R & S E K 8 9 5 / R & S E K 8 9 6
User Manual
f
List of Commands
6164.0717.02_01
> A3.44 >
A3.9 List of Commands
Code Function (entry in) Input
Output
(requested with ?)
Remark
A Address 00 to 99 01 to 99 see A3.8.1
B BFO frequency (Hz) >5000 to +5000 >5000 to +5000 see A3.3.2
BI Initiate BIT
Inquire BIT status
s
0= no fault
10= synthesizer
missing
1= synthesizer
defective
20= HF unit
missing
2= HF unit
defective
5= module bus
defective
60= IF / AF proces>
sor missing
6= IF / AF proces>
sor defective
7= IF Converter
R&S UX 895
defective
see A3.7.7
C Inquire CM status 0= no fault
1= synthesizer
defective
4= IF / AF proces>
sor defective
5= synthesizer
and IF / AF
processor
defective
see A3.7.8
CH Program channel list
0 to 999
up to 20
channels
0 to 999
up to 20 channels
see A3.6.4
CHc Clear channel list see A3.6.4
CL Inhibit channel 0 to 999 see A3.7.14
CLa Inhibit all channels see A3.7.14
CO Continue scanning see A3.4.3
see A3.5.3
see A3.6.3