V L F > H F R E C E I V E R
f
R & S E K 8 9 5 / R & S E K 8 9 6
User Manual
f
Scanning
STOP FRQ xxxx _ KHZ NEXT
STEP FRQ xxxx _ KHZ NEXT
THRESHOLD xxx _ dB
o
V NEXT
DWELLTIME xx _ MS NEXT
HOLDTIME xx _ F/T NEXT
or
HOLDTIME FOREVER F/T NEXT
(xxx= last stored values for start and stop fre>
quency, stepwidth, digital threshold,
dwell and hold times)
The flashing cursor (_) indicates that an entry is
being expected. Enter new start frequency,
stop frequency, stepwidth, digital threshold,
dwell time and / or hold time via the numeric
keypad.
Actuate softkey F / T when
f a hold time is to be entered via the numeric
keypad, but HOLDTIME FOREVER is
displayed,
or
Main Menu *
MOD CHM MEM SCN SYS >
Scanning Menu
FRQ CHP CHS S / C PRO
Programming Menu
FRQ CHP CHS CLR
Start Frequency
Entry NEXT
Stop Frequency
Entry NEXT
Stepwidth
Entry NEXT
Digital Threshold
Entry NEXT
Dwell Time
Entry NEXT
Hold Time
Entry F / T NEXT
see 3.1.17.6 to .8