V L F > H F R E C E I V E R S
f
R & S E K 8 9 5 / R & S E K 8 9 6
User Manual
f
Cables for Control and Status Data
EK 89x
X63
(TxD) .2
(TxD, inv.) .10
(RxD) .3
(RxD, inv.) .9
(GND) .7
Address: 01
EK 89x
X63
(TxD) .2
(TxD, inv.) .10
(RxD) .3
(RxD, inv.) .9
(GND) .7
Address: 02
EK 89x
X63
(TxD) .2
(TxD, inv.) .10
(RxD) .3
(RxD, inv.) .9
(GND) .7
Address: 03
EK 89x
X63
(TxD) .2
(TxD, inv.) .10
(RxD) .3
(RxD, inv.) .9
(GND) .7
Address: n
Interface
RS422>RS232C
(RxD)
(RxD, inv.)
(TxD)
(TxD, inv.)
(GND)
Computer
RxD
TxD
GND
Bus Driver *)
Fig. 2.21 Operating Mode: Four>wire Bus (RS485) with XON>XOFF Handshake
(S4 = E or F; see A1.4)
+5 V
510
]
510
]
150
]
120
]
*) If more than ten receivers
are operated on a bus, a
bus driver is required.
6164.0717.02_01
> 2.25 >