BUS<b>:CAN:SAMPlepoint <SamplePoint>
Sets the position of the sample point within the bit in percent of the nominal bit time.
See also: "Sample Point" on page 197.
Suffix:
<b>
.
1 | 2
Parameters:
<SamplePoint> Range: 10 to 90
Increment: 1
*RST: 50
Default unit: %
BUS<b>:CAN:BITRate
<BitRate>
Sets the number of transmitted bits per second.
Suffix:
<b>
.
1 | 2
Parameters:
<BitRate> Range: 100 to 5,04E06
Increment: Depends on the bit rate value
*RST: 50E03
Default unit: Bit/s
15.11.5.2 CAN - Trigger
To configure the protocol trigger, make sure to set first:
●
TRIGger:A:TYPE to BUS
●
TRIGger:A:SOURce to SBUS1 | SBUS2
TRIGger:A:CAN:TYPE....................................................................................................403
TRIGger:A:CAN:FTYPe..................................................................................................404
TRIGger:A:CAN:ITYPe................................................................................................... 404
TRIGger:A:CAN:ICONdition............................................................................................ 405
TRIGger:A:CAN:IDENtifier.............................................................................................. 405
TRIGger:A:CAN:DCONdition...........................................................................................405
TRIGger:A:CAN:DLC......................................................................................................405
TRIGger:A:CAN:DATA................................................................................................... 406
TRIGger:A:CAN:ACKerror...............................................................................................406
TRIGger:A:CAN:BITSterror............................................................................................. 406
TRIGger:A:CAN:CRCerror.............................................................................................. 406
TRIGger:A:CAN:FORMerror............................................................................................407
TRIGger:A:CAN:TYPE <TriggerType>
Specifies the trigger mode for CAN.
Serial Bus Analysis