ACQuire:POINts:ARATe?
Retrieves the sample rate of the ADC, that is the number of points that are sampled by
the ADC in one second.
Return values:
<AcquisitionRate> ADC sample rate
Range: 2.5E3 to 5,00E+009
Increment: 1,00E+003
*RST: 5,00E+009
Default unit: Hz
Usage: Query only
ACQuire:SRATe?
Returns the sample rate, that is the number of recorded waveform samples per second.
Return values:
<SampleRate> Range: 2 to 1,00E+011
Increment: depends on time base, waveform rate, number of
active channels
*RST: 1,00E+007
Default unit: Sa/s
Usage: Query only
15.2.4.4 Vertical
CHANnel<m>:STATe.....................................................................................................288
CHANnel<m>:COUPling.................................................................................................289
CHANnel<m>:SCALe.....................................................................................................289
CHANnel<m>:RANGe....................................................................................................289
CHANnel<m>:POSition...................................................................................................290
CHANnel<m>:OFFSet....................................................................................................290
CHANnel<m>:BANDwidth...............................................................................................290
CHANnel<m>:POLarity...................................................................................................291
CHANnel<m>:OVERload................................................................................................291
CHANnel<m>:SKEW......................................................................................................291
CHANnel<m>:THReshold...............................................................................................292
CHANnel<m>:LABel.......................................................................................................292
CHANnel<m>:LABel:STATe............................................................................................292
CHANnel<m>:STATe <State>
Switches the channel signal on or off.
Suffix:
<m>
.
Selects the input channel. The number of channels depends on
the instrument.
Command Reference