TRIGger:A:EDGE:COUPling <Coupling>
Sets the coupling for the trigger source.
Parameters:
<Coupling> DC | AC | HF
DC
Direct Current coupling. The trigger signal remains unchanged.
AC
Alternating Current coupling. A 5 Hz high pass filter removes the
DC offset voltage from the trigger signal.
HF
High frequency coupling. A 15 kHz high-pass filter removes lower
frequencies from the trigger signal. Use this mode only with very
high frequency signals.
*RST:  DC
TRIGger:
A:EDGE:FILTer:LPASs <State>
Turns an additional 5 kHz low-pass filter in the trigger path on or off. This filter removes
higher frequencies and is available with AC and DC coupling.
Parameters:
<State> ON | OFF
*RST:  OFF
TRIGger:A:EDGE:FILTer:NREJect <State>
Turns an additional 100 MHz low-pass filter in the trigger path on or off. This filter removes
higher frequencies and is available with AC and DC coupling.
Parameters:
<State> ON | OFF
*RST:  OFF
15.2.5.3 Width Trigger
TRIGger:A:WIDTh:POLarity............................................................................................305
TRIGger:A:WIDTh:RANGe..............................................................................................306
TRIGger:A:WIDTh:DELTa...............................................................................................306
TRIGger:A:WIDTh:WIDTh...............................................................................................306
TRIGger:A:WIDTh:POLarity <Polarity>
Sets the polarity of the pulse.
 
Command Reference