Remote Control
R&S
®
RTM20xx
311User Manual 1317.4726.02 ─ 01
TRIGger:A:LEVel<n>:RISetime:LOWer <Level>
TRIGger:A:LEVel<n>:RISetime:UPPer <Level>
Set the loer and upper voltage threshold, respectively. When the signal crosses these
levels, the slew rate measurement starts or stops depending on the selected polarity.
Suffix: 
<n>
.
1..5
The suffix is not relevant, the level applies to all sources.
Parameters:
<Level> Default unit: V
TRIGger:
A:RISetime:SLOPe <Polarity>
Sets the edge of whic the transition time is to be analyzed:
Parameters:
<Polarity> POSitive | NEGative
POSitive: rise time trigger
NEGative: Fall time trigger
*RST:  POS
TRIGger:A:RISetime:RANGe <Range>
Selects how the time limit of the rise or fall time is defined.
Parameters:
<Range> LONGer | SHORter | WITHin | OUTSide
LONGer | SHORter
Triggers on transition times longer or shorter than the time 
TRIGger:A:RISetime:TIME.
WITHin | OUTSide
Triggers on transition times inside or outside the time range TIMe
± DELTa. Use TRIGger:A:RISetime:TIME and TRIGger:A:
RISetime:DELTa to set the time range.
*RST:  LONG
TRIGger:A:RISetime:TIME <RiseTime>
For the ranges LONGer and SHORter, the command defines the minimum and maximum
transition times, respectively.
For the ranges WITHin and OUTSide, the command defines the center of a time range
which is defined using TRIGger:A:RISetime:DELTa.
See also: TRIGger:A:RISetime:RANGe
Parameters:
<RiseTime> Default unit: s
Command Reference