Electrical Adjustment
Grp / No. Item Function Range Initial Note
23 CSC_G_GP10 0 - 511 0
24 CSC_G_GP11 0 - 511 0
25 CSC_G_GP12 0 - 511 0
26 CSC_B_GP1 0 - 511 314
27 CSC_B_GP2 0 - 511 297
28 CSC_B_GP3 0 - 511 279
29 CSC_B_GP4 0 - 511 264
30 CSC_B_GP5 0 - 511 249
31 CSC_B_GP6 0 - 511 232
32 CSC_B_GP7 0 - 511 208
33 CSC_B_GP8 0 - 511 180
34 CSC_B_GP9 0 - 511 0
35 CSC_B_GP10 0 - 511 0
36 CSC_B_GP11 0 - 511 0
37 CSC_B_GP12 0 - 511 0
140 Panel-LR
0 PANEL_LR Panel Type Indication 0: Type-L, 1: Type-R - 0
1 PANEL_CHG Type Setting
Switch Type-R when the value is set to 20.
Switch Type-L when the value is set to 0.
0 - 20 10
200 Option
0 Logo Display Prohibition 0:Menu 1:Forced 0 - 1 0
1 RS232C Baud rate 0: 19200bps 1: 9600bps 0 - 1 0
4 CABLE SW Long Cable 0: Disable 1: Enable 0 - 1 0
6 Device Refresh Disable 0: Enable 1: Disable 0 - 1 0
8 PJ-NET HUNGUP CHK 0: Disable 1: Enable 0 - 1 0
51 Filter Warning Display 1:On 0:Off 0 - 1 1
53 Filter Counter Reset Times Read only 0 - 255 0
54 Factory Default Executed Times Read only 0 - 255 0
56 Menu Position (X) X Offset 0 - 1024 0
57 Menu Position (Y) Y Offset 0 - 1024 0
58 Lamp Go Out Lamp goes out 0 - 1 0
72 COMPONENT/RGB SW 0: Disable 1: Enable 0 - 1 1
80 Destination Language Set at Shipping 0:English 1:Japanese 0 - 1 0
140 OFFSET ADD MODE
Offset Tem Add Mode Display
0: No Addition, 1: Addtion
- 0
141 OFFSET ADD CHNG Apply Offset Change when the data is set 10 0 - 10 0
142 OFFSET Offset Temp - 10
143 TIMES OF OFFSET CHANGE 0 - 255 0
144 TIMES OF OFFSET RESET 0 - 255 0
201 Option (Signal) Not Used
0 FrameLock Option
Frame Lock Setting
0: OFF for PC
1: OFF for AV
2: OFF
3: ON Depending on Input Frequency
4: ON Depending on Input Frequency
0 - 4 4
204 Simulation mode
0 Scaler Enable 0: Off, 1: On 0 - 1 0
205 Spread Spectrum
0 Enable 0 - 1 0
1 Spread Rate Default 41 0 - 82 41
2 Spread Frequency Default 0 0 - 2 0
220 Projector Error Log
0 Warning_Log_1 Latest Error log 0 - 32767 0
: : : : :
49 Warning_Log_50 50th Error log 0 - 32767 0
50 Warning_Log Reset Log is cleared when the value is set to 10. 0 ~ 10 0
235 Shutter
0 Power ON_OFF Motion Shutter Warm - up Operation (0: Yes, 1: No) 0 - 1 Initial: 1 / Shipping: 0
1 CMP_TRM Chattering Detecting Term 0 - 32767 7000
2 OUT_DLY_TRM Output Term 0 - 32767 15000
3 CMP_CHK_CNT Count of Information Sync 0 - 15 5
4 OPEN_DLY Open Output Delay 0 - 63 30
5 CLOSE_DLY Close Output Delay 0 - 63 30