Electrical Adjustment
Grp / No. Item Function Range Initial Note
6 Position Check Time Position Check Time 1 - 255 30
7 Stop Mode
Shutter Operation in Stop Mode
0:Free, 1:Brake
0 - 1 0
8 Enable Close Cmd
Shutter Close Command
0:Disable, 1:Enable
0 - 1 1
9 Speed Control 0 - 255 0
10 Shutter Management Upper Time 180 - 999 480
239 Illumance Sensor 0 - 32767
0 Illuminance Factory Data 0 - 32767 10000
1 Illuminance Factory Data 0 - 32767 8300
2 Illuminance Factory Data 0 - 32767 7500
3 Illuminance Factory Data 0 - 32767 6250
4 Illuminance Model Data 0 - 32767 5281
5 Illuminance Model Data 0 - 32767 5138
6 Illuminance Model Data 0 - 32767 3891
7 Illuminance Model Data 0 - 32767 3806
-
10 Illuminance Factory Data 0 - 32767 5000
11 Illuminance Factory Data 0 - 32767 4150
12 Illuminance Factory Data 0 - 32767 3750
13 Illuminance Factory Data 0 - 32767 3125
14 Illuminance Model Data 0 - 32767 2585
15 Illuminance Model Data 0 - 32767 2569
16 Illuminance Model Data 0 - 32767 1882
17 Illuminance Model Data 0 - 32767 1895
-
20 Illuminance Factory Data 0 - 32767 5000
21 Illuminance Factory Data 0 - 32767 4150
22 Illuminance Factory Data 0 - 32767 3750
23 Illuminance Factory Data 0 - 32767 3125
24 Illuminance Model Data 0 - 32767 2655
25 Illuminance Model Data 0 - 32767 2586
26 Illuminance Model Data 0 - 32767 1938
27 Illuminance Model Data 0 - 32767 1904
240 Flow Calibration
0 Flow Calibration Exe
Flow Sensor Offset Calibration Start calibration when the value is
set to 1.
0 - 1 0
1 Flow Calibration Error Log
Log of Calibration Error (Read only)
255: Not Calibration
0: No Error
10: 1st Calibration Not Stable Airflow
11: 1st Calibration Out of Range
20: 2nd Not Stable Airow
21: 2nd Out of Range
100: 10th Calibration Not Stable Airflow
101: 10th Calibration Out of Range
- 255
2 Clog Check Enable Filter Clogged Detection by Flow Sensor (0: Disable, 1: Enable) 0 - 1 Initial: 0 / Shipping: 1
3 Air Inlet Check Enable Intake Vent Error Check (0: Disable, 1: Enable) 0 - 1 Initial: 0 / Shipping: 1
4 Time Limit Auto Scroll Enable (0: Disable, 1: Enable) 0 - 1 1
5 Clog Auto Cooling Enable Cooling on Clog (0: Disable, 1: Enable) 0 - 1 1
6 Scroll Fail Auto Cooling Enable Coolin on Scroll error (0: Disable, 1: Enable) 0 - 1 1
7 Time Force Scroll Enable Forced Scroll on Filter Timer Reached (0: Disable, 1: Enable) 0 - 1 0
241 Flow Ideal Data (Value will be set after calibration)
0 Flow Ideal Data 1 Flow Sensor Theory Value No.1 Corresponding to Fan Volt No.1 0 - 1023 290
1 Flow Ideal Data 2 Flow Sensor Theory Value No.2 Corresponding to Fan Volt No.2 0 - 1023 325
2 Flow Ideal Data 3 Flow Sensor Theory Value No.3 Corresponding to Fan Volt No.3 0 - 1023 350
3 Flow Ideal Data 4 Flow Sensor Theory Value No.4 Corresponding to Fan Volt No.4 0 - 1023 375
4 Flow Ideal Data 5 Flow Sensor Theory Value No.5 Corresponding to Fan Volt No.5 0 - 1023 390
5 Flow Ideal Data 6 Flow Sensor Theory Value No.6 Corresponding to Fan Volt No.6 0 - 1023 1023
6 Flow Ideal Data 7 Flow Sensor Theory Value No.7 Corresponding to Fan Volt No.7 0 - 1023 1023
7 Flow Ideal Data 8 Flow Sensor Theory Value No.8 Corresponding to Fan Volt No.8 0 - 1023 1023
242 Flow Calib. Fan Volt (Not Memorized)
0 Flow Calib Fan Volt 1 Flow Sensor Calibration Fan Volt No.1 [V x10] 0 - 255 50*
1 Flow Calib Fan Volt 2 Flow Sensor Calibration Fan Volt No.2 [V x10] 0 - 255 75
2 Flow Calib Fan Volt 3 Flow Sensor Calibration Fan Volt No.3 [V x10] 0 - 255 100
3 Flow Calib Fan Volt 4 Flow Sensor Calibration Fan Volt No.4 [V x10] 0 - 255 115
4 Flow Calib Fan Volt 5 Flow Sensor Calibration Fan Volt No.5 [V x10] 0 - 255 132*
5 Flow Calib Fan Volt 6 Flow Sensor Calibration Fan Volt No.6 [V x10] 0 - 255 255