Electrical Adjustment
Grp / No. Item Function Range Initial Note
6 Flow Calib Fan Volt 7 Flow Sensor Calibration Fan Volt No.7 [V x10] 0 - 255 255
7 Flow Calib Fan Volt 8 Flow Sensor Calibration Fan Volt No.8 [V x10] 0 - 255 255
243 Flow Calib Effective Difference (Not Memorized)
0 Flow Calib Effective Diff 1 Flow Sensor Calibration Range Diff No.1 [ADC] 0 - 1023 210
1 Flow Calib Effective Diff 2 Flow Sensor Calibration Range Diff No.2 [ADC] 0 - 1023 220
2 Flow Calib Effective Diff 3 Flow Sensor Calibration Range Diff No.3 [ADC] 0 - 1023 230
3 Flow Calib Effective Diff 4 Flow Sensor Calibration Range Diff No.4 [ADC] 0 - 1023 240
4 Flow Calib Effective Diff 5 Flow Sensor Calibration Range Diff No.5 [ADC] 0 - 1023 250
5 Flow Calib Effective Diff 6 Flow Sensor Calibration Range Diff No.6 [ADC] 0 - 1023 1023
6 Flow Calib Effective Diff 7 Flow Sensor Calibration Range Diff No.7 [ADC] 0 - 1023 1023
7 Flow Calib Effective Diff 8 Flow Sensor Calibration Range Diff No.8 [ADC] 0 - 1023 1023
244 Flow Clog Threshold (Not Memorized )
0 Flow Clog Threshold 1 Flow Sensor Clogged Threshold No.1[ADC] 0 - 1023 124
1 Flow Clog Threshold 2 Flow Sensor Clogged Threshold No.2[ADC] 0 - 1023 154
2 Flow Clog Threshold 3 Flow Sensor Clogged Threshold No.3[ADC] 0 - 1023 181
3 Flow Clog Threshold 4 Flow Sensor Clogged Threshold No.4[ADC] 0 - 1023 194
4 Flow Clog Threshold 5 Flow Sensor Clogged Threshold No.5[ADC] 0 - 1023 209
5 Flow Clog Threshold 6 Flow Sensor Clogged Threshold No.6[ADC] 0 - 1023 1023
6 Flow Clog Threshold 7 Flow Sensor Clogged Threshold No.7[ADC] 0 - 1023 1023
7 Flow Clog Threshold 8 Flow Sensor Clogged Threshold No.8[ADC] 0 - 1023 1023
10 Flow Inlet Err Threshold 1 Flow Sensor Intake Err Threshold No.1 [ADC] 0 - 1023 194
11 Flow Inlet Err Threshold 1 Flow Sensor Intake Err Threshold No.1 [ADC] 0 - 1023 224
12 Flow Inlet Err Threshold 1 Flow Sensor Intake Err Threshold No.1 [ADC] 0 - 1023 251
13 Flow Inlet Err Threshold 1 Flow Sensor Intake Err Threshold No.1 [ADC] 0 - 1023 264
14 Flow Inlet Err Threshold 1 Flow Sensor Intake Err Threshold No.1 [ADC] 0 - 1023 279
15 Flow Inlet Err Threshold 1 Flow Sensor Intake Err Threshold No.1 [ADC] 0 - 1023 1023
16 Flow Inlet Err Threshold 1 Flow Sensor Intake Err Threshold No.1 [ADC] 0 - 1023 1023
17 Flow Inlet Err Threshold 1 Flow Sensor Intake Err Threshold No.1 [ADC] 0 - 1023 1023
245 Filter Roll
0 Take Up Bend Remove Filter Flexure Starts. Exc when the Value is set to 1. 0 - 1 0
1 Take Up Times Remaining Times of Filter Scroll (Read only) - -
2 Take Up Time Reset
Filter Scroll Times Reset
Resets Remaining Scroll Times when the Value is set to 10.
0 - 10 0
3 Scroll Counter Reset Time Scroll Counter Reset Times (Read only) 0 - 255 -
4 Scroll Information Cartridge No 0 - 2 0
246 Flow Clog Monitor (Read only)
0 Real Flow Data Real Flow Data [ADC] (Read only) 0 - 1023 -
1 Ideal Flow Data Theory Flow Data (Read only) 0 - 1023 -
2 Flow Difference Data Flow Difference Data [ADC] (Read only) -1023 - 1023 -
3 Clog Detect Flow Difference Data Difference Data to judge the Filter Clogged [ADC] (Read only) 0 - 1023 -
4 Warn Detect Flow Difference Data
Difference Data to judge the Filter Clogged Warning [ADC] (Read
only)
0 - 1023 -
5 Press Add Data Add Data by Air Pressure (Read only) 0 - 1023 -
6 Filter Scroll Timer Timer for Filter Scroll [hour] (Read only) 0 - 32767 -
7 Air Inlet Err Difference Data Difference to judge the Intake Error 0 - 1023 -
247 Filter Scroll Time (Read only)
0 Filter 1st Cartridge Scroll Time 1
1st Filter Cartridge Used time at N times Scrolling [hour] (N:1-10)
0 - 32767 9999
1 Filter 1st Cartridge Scroll Time 2 0 - 32767 9999
2 Filter 1st Cartridge Scroll Time 3 0 - 32767 9999
3 Filter 1st Cartridge Scroll Time 4 0 - 32767 9999
4 Filter 1st Cartridge Scroll Time 5 0 - 32767 9999
5 Filter 1st Cartridge Scroll Time 6 0 - 32767 9999
6 Filter 1st Cartridge Scroll Time 7 0 - 32767 9999
7 Filter 1st Cartridge Scroll Time 8 0 - 32767 9999
8 Filter 1st Cartridge Scroll Time 9 0 - 32767 9999
9 Filter 1st Cartridge Scroll Time 10 0 - 32767 9999