5.2 Control
Printer
CL408e/412e
M-8400RVe
CL608e/612e
M-5900RVe
M-10e
M-8485Se/90Se/60Se/59Se M-84Pro-2/3/6 LC408e/412e
5.2 ESC+Z Data Send End
ESC+Z
HEX Code
ESC
Z
Parameter
<1B>16
<5A>16
NIL
Default Value
NIL
Valid Range and
Terms of
Command
When Power is Switched Off
The set command is not maintained
Valid Range within Items
The set command becomes invalid
Valid Range between Items
The set command becomes invalid
[Function]
To specify Data Send End
[Format]
<Z>
[Coding Example]
<A>
<V>100<H>200<P>2<L>0202<XM>ABCD
<Q>2
<Z>
[Supplementary Explanation]
1.To show the completion of item, must be used at the end of the item.
2.Data Send Start Specification <A> and Data Send End Specification <Z> must be used as a pair.
[Point]
1.Print motion is inactive when Data Send End Specification <Z> is not specified.
Data Send End