M-8485Se/90Se/60Se/59Se M-84Pro-2/3/6 LC408e/412e
13.8 ESC+YR Format Re-Call
ESC+YR
HEX Code
When Power is Switched Off
The set parameter is not maintained
The set parameter is valid until the next specification is made.
Valid Range between Items
The set parameter is valid until the next specification is made.
[Function]
To re-call and print out of the format which is registered at the Format Register Specification <YS>
[Format]
<YR>,aaa
● Parameter
a {Format Register No.} = valid range : 1~999
[Coding Example]
<A>
<CC>1
<YR>,01
</D>,1,DEF
</D>,2,78901
</D>,3,49000238
<Q>2
<Z>
[Supplementary Explanation]
1. Format Re-Call Specification <YR> cannot re-call the multiple format in between of Data Send Start Specification <A> ~ Data Send End
Specification <Z>.
2. Use it with Field Print Specification </D> as a pair.
3. LC408e/412e does not support optional memory card. Please specify {Flash ROM} with Card Slot Specification <CC>.