M-8485Se/90Se/60Se/59Se M-84Pro-2/3/6 LC408e/412e
7.13 ESC+WD Co
When Power is Switched Off
The set parameter is not maintained
The set parameter becomes invalid
Valid Range between Items
The set parameter becomes invalid
[Function]
To copy the specified range from an optional location to another optional location
[Format]
<WD>VaaaaHbbbbYccccXdddd
● Parameter
a {Vertical Start Point of Copy Source} = valid range : refer to next page table
b {Horizontal Start Point of Copy Source} = valid range : refer to next page table
c {Vertical Dot Size of Copy Source} = valid range : refer to next page table
d {Horizontal Dot Size of Copy Source} = valid range : refer to next page table
[Coding Example] Vertical Start Point of Copy Source:50, Horizontal Start Point of Copy Source:50,
Vertical Dot Size of Copy Source:200, Horizontal Dot Size of Copy Source:400
<A>
<V>50<H>50<P>2<L>0202<XU>ABCD
<V>300<H>100<WD>V50H50Y200X400
<Q>2
<Z>
[Supplementary Explanation]
1. Specify location for copy destination, specify Print Vertical Position Specification <V> and Print Horizontal Position Specification
<H> before the Copy Specification <WD> inside of the label.
2. Do not specify the position of copy destination within the copy source.
3. If print start position of copy area exceed printable area, it will become command error and stop printing.
Dot line portion shows the copy area.
Actual print portion is 「ABCD」.
Copy within Labels (Part Copy)