M-8485Se/90Se/60Se/59Se M-84Pro-2/3/6 LC408e/412e
9.2 ESC+D Barcode (ratio 1 : 2)
ESC+D
HEX Code
When Power is Switched Off
The set parameter is not maintained
The set parameter becomes invalid
Valid Range between Items
The set parameter becomes invalid
[Function]
To specify barcode ratio of 1 : 2 of narrow bar and wide bar.
[Format]
<D>abbcccn~n
● Parameter
a {Barcode Type} = Refer to the following table
b {Thin Bar Width} = 01~12 (dot)
c {Barcode Height} = 001~999 (dot)
n {Print Data} = Data
Barcode Type (The ratio of module structure may not exist based on different barcode)
Set Start/Stop Character at Print Data.
Start/Stop Character becomes {A, B, C, D, E, N, T, a, b, c, d, e, n, t}
e.g.) If barcode print data is{123}, specify it as{A123A}.
Barcode character pitch becomes valid.
Print data can be referred to NW-7 code table.
Set Start/Stop character at Print Data.
Start/Stop Character becomes{*}.
e.g.) If barcode print data is{12345}, specify it as{*12345*}.
Barcode character pitch becomes valid.
Print data can be referred to CODE39 code table.
Specify the print data at even number digit.
If odd number digit is specified, fill a “0” at the beginning of print data.
Print data can be referred to Interleaved 2 of 5 code table.
Guide Bar : YES, Explanation Character : NIL
Print data can be referred to JAN/EAN-13 code table.
Guide Bar : YES, Explanation Character : NIL
Print data can be referred to JAN/EAN-8 code table.
Fixed
5 Industrial 2 of 5
Barcode character pitch becomes valid.
Print data can be referred to Industrial 2 of 5 code table.
Barcode character pitch becomes valid.
Print data can be referred to Matrix 2 of 5 code table.
Guide bar : YES, Explanation Character : NIL
Print data can be referred to UPC-A code table.
Fixed
[Coding Example 1] Barcode Type : NW-7, Thin Bar Width : 03, Barcode Height : 120, Print Data : A1234A
<A>
<V>100<H>100<D>003120A1234A
<Q>2
<Z>
Barcode (ratio 1 : 2)