[Function]
Specifying QR Code (Model 1)
[Format] (Setup part)
<2D31>,a, bb, c, d(,ee, ff, gg)
●Parameter
a
[Error Correction Level] = L : 7%
M : 15%
Q : 25%
H : 30%
b [Size of one side of cell] = Valid Range : 01 to 32 dots
* Recommend to specify more than 2 dots in the 8 dots/mm and 12 dots/mm for scanner readability.
c [Data setup mode = 0 : Manual setup
1 : Automatic setup
* Note: You need to change the method of specifying print data with this setting.
d [Concatenation mode] = 0 : Normal mode
1 : Concatenation mode
Following parameter must be specified when specifying 1 (Concatenation mode) in Concatenation mode.
Omit following parameter in normal mode.
e [Number of partitions of concatenation mode] = Valid Range : 01 to 16
* Number of partitions: Specifying how many QR code are to be concatenated divided by Concatenation
mode.
f [Sequential number partitioned by concatenation mode] = Valid Range : 01 to 16
* Sequential number: Specifying what number is it of divided QR code.
g [Concatenation mode parity data] = Valid Range : 00 to FF
* Parity data: Specifying exclusive OR of all the print data in divided QR code with HEX characters.
[Format] (Data part)
Manual setup (Data setup mod)
<DS>k,n~n
* Use when input mode specification is Numeric mode, Alphanumeric mode and Kanji mode.
<DN>mmmm, n~n * Use when specifying by binary.
Automatic setup (Data setup mode)
<DN>mmmm, n~n * Change input mode automatically according to input data.
●Parameter
k [Input mode] = 1 : Numeric mode
2 : Alphanumeric mode
3 : Kanji mode (Shift JIS Kanji)
* Specify only when specifying Manual setup in Data setting mode.
* There is binary specification other than above, but data specification command is different.
m [Number of data] = Valid Range : 1 to 486
* Specify when specifying Automatic setup in Data setting mode or specifying binary specification in Manual
setup.
n [Print data] = Data
QR Code (Model 1)