M-8485Se/90Se/60Se/59Se M-84Pro-2/3/6 LC408e/412e
9.4 ESC+BD Barcode (ratio 2 : 5)
ESC+BD
HEX Code
When Power is Switched Off
The set parameter is not maintained
The set parameter becomes invalid
Valid Range between Items
The set parameter becomes invalid
[Function]
To specify barcode ratio of 2 : 5 for narrow and wide bar.
[Format]
<BD>abbcccn~n
● Parameter
a {Barcode Type} = refer to the following table
b {Thin Bar Width} = 01~12 (dot)
c {Barcode Height} = 001~999 (dot)
n {Print Data} = data
Barcode Type (Ratio of module structure may not exit based on different barcode)
Specify those include Start/Stop Character at print data.
Start/Stop Character becomes{A, B, C, D, E, N, T, a, b, c, d, e, n, t}.
e.g.) When barcode print data is{123}, specify it with{A123A}
Barcode character pitch becomes valid.
Print data can be referred to NW-7 code table.
Specify those include Start/Stop Character at print data.
Start/Stop Character becomes{*}.
e.g.) When barcode print data is{12345}, specify it with{*12345*}
Barcode character pitch becomes valid.
Print data can be referred to CODE39 code table.
Specify print data by even number digit.
When specified by odd number digit, fill “0” in the beginning of printer data.
Print data can be referred to Interleaved 2 of 5 code table.
Guide Bar : YES, Explanation Word : YES
Print data can be referred to JAN/EAN13 code table.
Guide Bar : YES, Explanation Word : YES
Print data can be referred to JAN/EAN8 code table.
Fixed
5 Industrial 2 of 5
Barcode character pitch becomes valid.
Print data can be referred to Industrial 2 of 5 code table.
Barcode character pitch becomes valid.
Print data can be referred to Matrix 2 of 5 code table.
Guide Bar : YES, Explanation Word : YES
Print data can be referred to UPC-A code table.
Fixed
[Coding Example 1] Barcode Typ e:NW-7, Thin Bar Width:03, Barcode Height:120, Print Data:A1234A
<A>
<V>100<H>100<BD>003120A1234A
<Q>2
<Z>
Barcode (ratio 2 : 5)