16
5.4 Control
Printer
CL408e/412e
M-8400RVe
CL608e/612e
M-5900RVe
M-10e
M-8485Se/90Se/60Se/59Se M-84Pro-2/3/6 LC408e/412e
5.4 ESC+ID Job ID Number
ESC+ID
HEX Code
ESC
ID
Parameter
<1B>16
<49>16<44>16
aa
Default Value
aa=<20>16
Valid Range and
Terms of
Command
When Power is Switched Off
The set parameter is not maintained
Valid Range within Items
The set parameter is valid until the next specification is made
Valid Range between Items
The set parameter becomes invalid
[Function]
To specify Job ID No for status send
[Format]
<ID>aa
●Parameter
a {Job ID No} = Valid Range : 00~99
[Coding Example] Job ID No:01
<A>
<ID>01
<V>200<H>100<P>0<$>B,100,100,6
<$=>SATOPRINTER
<Q>2
<Z>
[Supplementary Explanation]
1.When status return is used on interface protocol, the specified Job ID No can be set at the telegraphic status.
2.Status can be confirmed by sending status request (ENQ).
3.Program it within items and use it whle printing is performed by Data Send Start Specification <A> ~ Data Send End Specification
<Z>.
[Point]
1.Status return interface protocol is valid when status request (ENQ) during printing(QTY≠0, includes when Offline and Error occurs) is
received.
2.At the status return interface protocol, if status request (ENQ) is returned not during printing, (QTY=0, no received data when power
is switched on), set a space (20H) at the status and then return it.
3.Within items of Data Send Start Specification<A> ~ Data Send Complete Specification <Z>, the final specified value is valid when
Job ID Number Specification <ID> is used more than twice.
4.The details can be referred to “Interface Specification”
Job ID Number