Using the EM 6000
115
Status messages
In certain situations, the EM 6000 display may show status messages and
error messages. For messages relating to errors that can impair function,
the red triangle to the right of the display for the particular channel also
lights up.
►
Message Explanation
No Link No transmitter connected.
▷ Check the transmitter radio link with the
receiving channel. See “Establishing a
radio link”.
Low Signal The reception quality between the transmit-
ter and receiver is poor (RF A or RF B below
-85 dBm, LQI between 1% and 19%)
▷ Check the transmitter’s radio link to the
receiving channel and switch to a differ-
ent frequency if necessary. See “Estab-
lishing a radio link”.
▷ Check that the antennas are positioned
correctly. See “Connecting remote an-
tennas”, “Connecting rod antennas”, or
“Recommendations for using anten-
nas”.
Low battery The transmitter’s batteries or rechargeable
battery pack have little battery life remain-
ing (less than 30 minutes).
▷ Replace the rechargeable battery or
batteries.
Sync ok The synchronization of the receiving chan-
nel with the transmitter was successful.
Sync Fail
No Frequency
The auto setup function cannot provide any
more free frequencies for the transmitter
frequency range.
Sync Fail
Frequency Rejected
The transmitter frequency range is incom-
patible with the frequency set in the receiv-
ing channel.
▷ Set a different frequency in the receiv-
ing channel. See “Frequency menu
item”.
Sync Fail
Timeout
The synchronization of the receiving chan-
nel with the transmitter was unsuccessful.
The infrared interface for the receiver may
not have been able to establish a link to the
infrared interface of the transmitter.
▷ Hold the transmitter in front of the infra-
red interface for the receiver correctly.
See “Synchronizing devices”.