Using the SK 6000
130
The range in which the input can be adjusted varies depending on the
microphone or line-cable used.
Low Cut menu item
In this menu item, you can adjust the value for the low cut filter.
Setting: 30 Hz, 60 Hz, 80 Hz, 100 Hz, 120 Hz
Alternatively, you can also adjust the low cut filter in the receiver and syn-
chronize it with the transmitter. See “Sync Settings menu item”.
Display menu item
In this menu item, you can choose whether the home screen on the
transmitter display shows the set frequency, the frequency preset,
or the name of the transmitter or radio link.
Alternatively, you can also adjust the home screen display in the receiver
and synchronize it with the transmitter. See “Sync Settings menu item”.
Lock menu item
In this menu item, you can activate or deactivate the lock-off for
the transmitter.
Alternatively, you can also adjust the lock-off in the receiver and synchro-
nize it with the transmitter. See “Sync Settings menu item”.
To enable the lock-off:
Open the Lock menu item and set the value to On.
Save your entry by pressing the SET button.
The automatic lock-off function will remain activated.
To disable the lock-off:
Press the SET button to open the menu.
Use the UP and DOWN buttons to navigate to the Lock menu item.
Press the SET button to open the Lock menu item.
The message LOCKED is shown on the display.
Press the UP or DOWN button.
The message UNLOCK is shown on the display.
Press the SET button.
The lock-off function is now temporarily disabled.
Press the SET button again right away.
Press the UP or DOWN button to set the value to OFF.
Press the SET button to confirm your setting.
The lock-off function is now disabled.
Test Tone menu item
In this menu item, you can activate a 1 kHz test tone that the trans-
mitter transmits instead of the input signal. Use this function to
level out the system and during the walk test.