9·50
Degree of match inspection
9
Continued from the previous page: When the GRAY-IMG-PROC (gray scale processing mode) is selected.
[Example of recording]
- This example shows a recorded image when model 0 (positioning) is set to SEARCH
(search) and model 1 (object to be measured) is set to YES (SEARCH) (do not search)
- Example of a horizontal line measurement window (SEARCH)
- Example of a vertical line measurement window (SEARCH)
Return to the [MEASURING COND] (measurement condition) menu and select item 6 UPPER MENU.
Go to page 9·53
The reference image for model 0 (positioning)
The search area for model 0 (positioning)
(Measurement window: rectangular)
The reference image for model 1 (object to be measured)
The search area for model 1 (object to be measured)
The detection coordinates for model 0 (positioning)
The detection coordinates for model 1 (object to be measured)
Crosshair cursor
(detection coordinates)
Solid line (reference line) Dotted line (search line)
Crosshair cursor
(detection coordinates)
Solid line (reference line) Dotted line (search line)