9·51
Degree of match inspection
9
Continued from page 9·48: When the BINRY-IMG-PROC (binary processing mode) is selected.
Continued on the following page
· You can switch between displaying all of the headings together and displaying each one separately
using the ESC key.
1REFERENCE IMAGE MOVE UP.L(224,208) LO.R(287,271) REG. DISP
2DETECTED COORD CNTRFREE(255,240)
3THRESHOLD VALUE U.LM255L.LM100(0~255)
4INVERT B/W NOYES
9BINARY PROCESS FIXEDTHRSHOLD-ADJ (VAR-DIFF VAR-RATE)
0IMAGE PRE-PROCESS
OFFSMOOTHEDGE-EMPHASIS
ALL-EDGEHORZ-EDGEVERT-EDGE
qBINARY NOIS FILTR NOEXPD.CONTR.CONTR.EXPD.
wNUM. OF FILTR PASS
EXPD.0(0~5) CONTR0(0~5)
eUPPER MENU
Menu
1REFERENCE IMAGE
2DETECTED COORD
(detection coordinates)
3THRESHOLD VALUE
4INVERT B/W
(black and white
inversion)
9BINARY PROCESS
(the binary conversion
process)
0IMAGE PRE-PROCESS
(image pre-processing)
qBINARY NOIS FILTR
(eliminating binary
noise)
wNUM. OF FILTR PASS
(the number of binary
noise elimination
processing)
eUPPER MENU
Setting details
Record a reference image.
Set the position of the cursor inside the measurement window.
· If FREE is selected, then position of cursor is optional.
Set the upper and lower limits for binary conversion within the range
of 0 to 255.
-See page 9·7 Setting threshold values, in Shared settings
Set the inversion of black and white in the image to YES or NO.
· Selecting NO means that the white area is measured after the
image has been converted to binary values.
· Selecting YES means that the black area will be measured after the
image has been converted to binary values.
Select either fixed or threshold value correction as the binary
conversion processing method. (VAR-DIFF or VAR-RATE).-See
page 9·8 Methods for binary conversion in Shared settings
Select a method for pre-processing the image data.
-See page 9·9, Pre-processing in Shared settings
Select a method for eliminating binary noise.
-See page 9·10, Methods for eliminating noise from binary images,
expansion/contraction and, Eliminating binary noise, in Shared
settings
Separately set the number of cycles that the expansion and
contraction binary noise elimination processes will be repeated (0 to
5).
This will return you to the [MEASURING COND] (measurement
condition) menu.