Part Protective
c
oating
1)
Type code Part number
CANopen gateway No FX0-GCAN00000 1044076
Yes FX0-GCAN00010 1118379
DeviceNet gateway No FX0-GDEV00000 1044077
CC-Link gateway No FX0-GCC100200 1085195
EFI-pro gateway No FX3-GEPR00000 1069070
Yes FX3-GEPR00010 1112296
1)
For more challenging ambient conditions (e.g., resistance to sulfur).
Expansion modules
T
able 195: Ordering data for extension modules
Part Protective
c
oating
1)
Type code Part number
I/O module
8 safety inputs, 4 safety outputs, plug-in
dual level spring terminals
No FX3-XTIO84002 1044125
Yes FX3-XTIO84012 1050618
I/O module
8 s
afety inputs, plug-in dual level spring
terminals
No FX3-XTDI80002 1044124
Yes FX3-XTDI80012 1050617
I/O module
8 s
afety inputs, 4 or 6 non-safe outputs,
plug-in dual level spring terminals
No FX3-XTDS84002 1061777
Yes FX3-XTDS84012 1112301
I/O module
6 or 8 non-
safe inputs, 8 or 6 non-safe
outputs, plug-in dual level spring termi‐
nals
No FX0-STIO68002 1061778
Yes FX0-STIO68012 1112297
Motion Control
F
or connecting two encoders
No FX3-MOC000000 1062344
Motion Control
F
or connecting two encoders
No FX3-MOC100000 1057833
Yes FX3-MOC100010 1112300
Analog input module
Connection of two analog sensors
No FX3-ANA020002 1051134
Yes FX3-ANA020012 1112299
1)
For more challenging ambient conditions (e.g., resistance to sulfur).
Relay modules
T
able 196: Ordering data of relay modules
Part Protective
c
oating
1)
Type code Part number
Relay module
2 normally open contacts and 1 24V DC
signal output, plug-in spring terminals
No UE410-2RO4 6032677
Yes UE410-2RO401 1118380
Relay module
4 nor
mally open contacts and 2 24V DC
signal outputs, plug-in spring terminals
No UE410-4RO4 6032676
Yes UE410-4RO401 6053182
Safety relay
Out
put expansion module for OSSDs
2 enabling current paths
No RLY3-OSSD1 1085343
13 ORDERING INFORMATION
180
O P E R A T I N G I N S T R U C T I O N S | Flexi Soft Modular Safety Controller 8012478/1IG6/2023-02-24 | SICK
Subject to change without notice

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK Flexi Soft and is the answer not in the manual?

SICK Flexi Soft Specifications

General IconGeneral
Safety Integrity Level (SIL)SIL3
Performance Level (PL)PL e
ProgrammingFlexi Soft Designer
Power Supply24 V DC
Safety ProtocolsPROFIsafe, CIP Safety
Protection ClassIP20
Number of I/OsConfigurable
Operating Voltage24 V DC
Power ConsumptionDepends on configuration
Dimensions (W x H x D)Varies depending on the module configuration
WeightVaries depending on the module configuration
Number of Safety InputsConfigurable
Number of Safety OutputsConfigurable
Safety StandardIEC 61508, IEC 62061, ISO 13849
Operating Temperature0°C to +55°C
Response Time< 10 ms (typical)
Storage Temperature Range-25°C to +70°C
Relative Humidity15 % ... 95 %, non-condensing

Related product manuals