Internal circuitry for diode module DM8-A4K
Figure 50: Internal circuitry for diode module DM8-A4K
5.4.1.7 Operating mode selector switch
Table 62: Connection of operating mode selector switch
Electrical connection: example with FX3-XTIO
Operating mode selector switch (1 of 2), at 24
V
Channel 1: contact between 24 V and I1
Channe
l 2: contact between 24 V and I2
Operating mode selector switch (1 of 2), at test
out
put
Channel 1: contact between X1 and I1
Channel 2: contact between X1 and I3
Table 63: Function with operating mode selector switch
Function Notes
Tested Possible
NOTE
Oper
ating mode selector switches without test signals support between 2 and
8 operating modes; operating mode selector switches with test signals support
between 2 and 4 operating modes.
When wiring the tested operating mode selector switch, please remember that if
you are using a test output with an odd number (X1, X3, X5, X7), inputs with odd
numbers (I1, I3, I5, I7) must be used; if you are using a test output with an even
number (X2, X4, X6, X8), inputs with even numbers (I2, I4, I6, I8) must be used.
You will find more information in the operating instructions for the operating mode
selector switches.
5.4.1.8 Volt-free contacts
The configuration software provides a range of volt-free contacts for “free” arrangement
of cont
act elements. This enables a variety of N/C / N/O combinations to be imple‐
mented with and without testing. There are also start and stop button, reset button,
and external device monitoring (EDM) elements available.
Table 64: Functions with volt-free contacts
Function Notes
Tested Possible
Series connection Possible
Discrepancy time See the report in the configuration software
ELECTRICAL INSTALLATION 5
8012478/1IG6/2023-02-24 | SICK O P E R A T I N G I N S T R U C T I O N S | Flexi Soft Modular Safety Controller
83
Subject to change without notice

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK Flexi Soft and is the answer not in the manual?

SICK Flexi Soft Specifications

General IconGeneral
Safety Integrity Level (SIL)SIL3
Performance Level (PL)PL e
ProgrammingFlexi Soft Designer
Power Supply24 V DC
Safety ProtocolsPROFIsafe, CIP Safety
Protection ClassIP20
Number of I/OsConfigurable
Operating Voltage24 V DC
Power ConsumptionDepends on configuration
Dimensions (W x H x D)Varies depending on the module configuration
WeightVaries depending on the module configuration
Number of Safety InputsConfigurable
Number of Safety OutputsConfigurable
Safety StandardIEC 61508, IEC 62061, ISO 13849
Operating Temperature0°C to +55°C
Response Time< 10 ms (typical)
Storage Temperature Range-25°C to +70°C
Relative Humidity15 % ... 95 %, non-condensing

Related product manuals