EasyManuals Logo

Siemens SCALANCE W1780 User Manual

Siemens SCALANCE W1780
368 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #267 background imageLoading...
Page #267 background image
Port VID
Select the VLAN ID from the drop-down list. Only VLAN IDs defined on the "VLAN >
General" page can be selected.
If a received frame does not have a VLAN tag, it has a tag with the VLAN ID specified here
added to it and is sent according to the rules at the port.
Acceptable Frames
Specify which types of frames will be accepted. The following alternatives are possible:
Tagged Frames Only
The device discards all untagged frames. Otherwise, the forwarding rules apply
according to the configuration.
All
The device forwards all frames.
No Change
If "No Change" is selected, the entries of the corresponding column in table 2 remain
unchanged.
Ingress Filtering
Specify whether the VID of received frames is evaluated.
You have the following options:
Enabled
The VLAN ID of received frames decides whether they are forwarded: To forward a
VLAN tagged frame, the receiving port must be a member in the same VLAN. Frames
from unknown VLANs are discarded at the receiving port.
Disabled
All frames are forwarded.
No Change
If "No Change" is selected, the entries of the corresponding column in table 2 remain
unchanged.
Procedure
1. In the row of the port to be configured, click on the relevant cell in the table to configure it.
2. Enter the values to be set in the input boxes as follows.
3. Select the values to be set from the drop-down lists.
4. Click the "Set Values" button.
Configuring with Web Based Management
6.7 "Layer 2" menu
SCALANCE W1780/W1740 according to IEEE 802.11ac Web Based Management
Configuration Manual, 11/2019, C79000-G8976-C485-03 267

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE W1780 and is the answer not in the manual?

Siemens SCALANCE W1780 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE W1780
CategoryWireless Access Point
LanguageEnglish

Related product manuals