Page #274 background imageLoading...
Page #274 background image
Path Cost
The path costs from this port to the root bridge. The path with the lowest value is selected
as the path. If several ports of a device have the same value, the port with the lowest port
number will be selected.
If the "Cost Calc." box has the value "0", the automatically calculated value is shown.
Otherwise, the value of the "Cost Calc." box is displayed.
The calculation of the path costs is largely based on the transmission speed. The higher the
achievable transmission speed is, the lower the value of the path costs.
Typical values for path costs with rapid spanning tree:
1000 Mbps = 20,000
100 Mbps = 200,000
10 Mbps = 2,000,000
The values can, however, also be set individually.
State
Displays the current state of the port. The values are only displayed and cannot be
configured. The "State" parameter depends on the configured protocol. The following is
possible for status:
Disabled
The port only receives and is not involved in STP, MSTP and RSTP.
Discarding
In the "Discarding" mode, BPDU frames are received. Other incoming or outgoing
frames are discarded.
Listening
In this status, BPDUs are both received and sent. The port is involved in the spanning
tree algorithm.
Learning
Stage prior to the forwarding status, the port is actively learning the topology (in other
words, the node addresses).
Forwarding
Following the reconfiguration time, the port is active in the network; it receives and
forwards data frames.
Fwd. Trans
Specifies the number of changes from the "Discarding" status to the "Forwarding" status.
Configuring with Web Based Management
6.7 "Layer 2" menu
SCALANCE W1780/W1740 according to IEEE 802.11ac Web Based Management
274 Configuration Manual, 11/2019, C79000-G8976-C485-03

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE W1780 and is the answer not in the manual?

Siemens SCALANCE W1780 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE W1780
CategoryWireless Access Point
LanguageEnglish

Related product manuals