EasyManua.ls Logo

Siemens SCALANCE W1780 - Page 361

Siemens SCALANCE W1780
368 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Severity Warning
Facility local0
Limiting the number of simultaneous sessions
Log text {protocol}: The maximum number of {max sessions} concurrent login session ex‐
ceeded.
Standard IEC 62443-3-3 Reference: SR2.7
Description The maximum number of parallel connections is exceeded.
Example WBM: The maximum number of 8 concurrent login session exceeded.
Severity Warning
Facility local0
Non-deniability (change configuration)
Log text Device configuration changed.
Standard IEC 62443-3-3 Reference: SR2.12
Description The device configuration has been changed permanently.
Example Device configuration changed.
Severity Info
Facility local0
Data backup in automation system (backup)
Log text {protocol}: User {user name} saved file type ConfigPack
Standard IEC 62443-3-3 Reference: SR7.3
Description Backup completed
Example WBM: User admin saved file type ConfigPack..
Severity Info
Facility local0
Log text {protocol}: Saved file type ConfigPack.
Standard IEC 62443-3-3 Reference: SR7.3
Description Backup completed
Example TFTP: Saved file type ConfigPack
Severity Info
Facility local0
Log text {protocol}: User {user name} failed to save file type ConfigPack.
Standard IEC 62443-3-3 Reference: SR7.3
Description Backup failed
Example WBM: User admin failed to save file type ConfigPack.
Appendix E
E.3 Syslog messages
SCALANCE W1780/W1740 according to IEEE 802.11ac Web Based Management
Configuration Manual, 11/2019, C79000-G8976-C485-03 361

Table of Contents

Related product manuals