Commissioning
5.2 Basic commissioning
SINAMICS G110M Operating Instructions
114 Operating Instructions, 04/2015, FW V4.7.3, A5E31298649B AD
Setting the AS-i address of slave 2
1.
Press the
button; the display shows the text
SEArcH
followed by
uSE 0
.
A small 0 is displayed to the left of the display and
the number of the first slave that has already been
allocated to slave 1 is shown at the bottom of the
display.
2.
Press the
button to select this number.
SEt 0
appears and the small
0
in the left of the dis-
play starts flashing.
3.
Press the
button until you reach the required number.
By pressing both the
and simultaneously, you can toggle between A and B
identifiers of the address.
4.
Press the
button to accept this number.
ProG
is displayed briefly.
Both of the numbers allocated to the slaves are now
displayed in the lower part of the screen.
Changing existing addresses of the AS-i slaves
If the allocated addresses used two different numbers, for example, 10A and 11A, then if one
of the slave addresses is reset to 0 the other slave is not affected.
If the allocated addresses use the same number, for example, 20A and 20B, then if one
slave addresses is reset to 0, then both slaves numbers will be reset to 0.
Modifying an existing address of a single slave within the Inverter will not affect the address
of the other slave.