6 Assi
nin
Parameters to the Control and the PLC Pro
ram
6
03.96
6.10 Linear motors (1FN1 and 1FN3 motors)
6-153
Siemens AG 2000 All Rights Reserved
SINUMERIK 840D Installation and Start-Up Guide (IAD) – 04.00 Edition
3. Measuring system
Is an incremental or an absolute (EnDat) measuring system installed?
a) Incremental measuring system:
– Graduations _ _ _ _ _ _ mm
– Number of zero markers _ _ _ _ _ _
b) Absolute measuring system:
– Graduations _ _ _ _ _ _ mm
Determine the positive drive direction:
Where is the positive count direction of the measuring system? (see
Section 6.10.6)
––> invert the actual velocity value? j yes j no
4. Wiring
– Power section (connection with phase sequence UVW, CW rotating field)
– PE conductor connected?
– Shield attached?
– Various methods of temperature sensor evaluation
a) KTY84 evaluation via SIMODRIVE 611D only
b) Evaluation via SIMODRIVE 611D and external devices
c) Evaluation by external devices only
Note:
In case a) a temperature sensor coupling lead (dongle) must be con-
nected between –X411 and the measuring system.
(See also PJLM/CON/Connections:
Section “Encoder connection”).
5. Measuring system cable
Check whether the measuring system cable is correctly attached to con-
nector X411 or to the adapter on the temperature sensor coupling lead.
(See also PJLM/CON/Connections:
Section “Encoder connection”).
04.0004.00