10
03.96
10.10 Automatic controller setting (only MMC 103, SW 4.3 and higher)
10-240
 Siemens AG 2000 All Rights Reserved
SINUMERIK 840D Installation and Start-Up Guide (IAD) – 04.00 Edition
10.10.2 Input options for self-optimization
Fig. 10-17 Mechanical system measurement
Amplitude:
Entered in % of maximum current of power section.
Bandwidth:
The bandwidth should only be changed if the previous optimization runs do not
produce satisfactory results (can only be changed in mechanical system part 1).
Averaging:
Should only be reduced if the traversing range of the machine is inadequate.
Offset:
Constant velocity during measurement (changing positive/negative sign for
optimum utilization of traversing range).
Fig. 10-18 Current control loop measurement
Mechanical system
measurement
Current control
loop measurement