EasyManuals Logo

Siemens SINUMERIK 810D Installation And Startup Guide

Siemens SINUMERIK 810D
327 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #240 background imageLoading...
Page #240 background image
10
03.96
10.10 Automatic controller setting (only MMC 103, SW 4.3 and higher)
10-240
 Siemens AG 2000 All Rights Reserved
SINUMERIK 840D Installation and Start-Up Guide (IAD) – 04.00 Edition
10.10.2 Input options for self-optimization
Fig. 10-17 Mechanical system measurement
Amplitude:
Entered in % of maximum current of power section.
Bandwidth:
The bandwidth should only be changed if the previous optimization runs do not
produce satisfactory results (can only be changed in mechanical system part 1).
Averaging:
Should only be reduced if the traversing range of the machine is inadequate.
Offset:
Constant velocity during measurement (changing positive/negative sign for
optimum utilization of traversing range).
Fig. 10-18 Current control loop measurement
Mechanical system
measurement
Current control
loop measurement
10 Drive Optimization with Start-Up Tool
05.9805.98

Table of Contents

Other manuals for Siemens SINUMERIK 810D

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK 810D and is the answer not in the manual?

Siemens SINUMERIK 810D Specifications

General IconGeneral
BrandSiemens
ModelSINUMERIK 810D
CategoryControl Unit
LanguageEnglish

Related product manuals